Centurion C5 Series configurable controller for compressor and engine-driven industrial systems
Fully Configurable Control
Industrial Grade Reliability | Scalable I/O System | Industrial Grade Reliability
Power Generation · Industrial Engines · Marine

Centurion™ C5 Series Configurable Controller

The Centurion™ C5 Series Configurable Controller is an advanced industrial control and monitoring system designed for compressors, pump systems, and engine-driven applications. Built for marine, oil & gas, and heavy industrial environments, the controller provides expandable I/O modules, configurable PID control loops, and multi-protocol communication including Modbus and CAN. It enables real-time performance monitoring, alarm management, and automated shutdown protection in critical operations.

2 X USB host type A
LED Display
1 X RS485
30 VDC Max Voltage
  • Fully Configurable Control Platform: The Centurion™ C5 Series Configurable Controller allows flexible configuration using PC-based software without complex programming. All I/O points can be customized to match compressor, pump, or engine-driven system requirements.
  • Expandable I/O Architecture: Optional MX4-R2 and MX5-R2 expansion modules increase analog, digital, and temperature input capacity. This enables scalable integration for multi-stage compressors and complex industrial applications.
  • Advanced PID and Linear Control Loops: Supports multiple configurable control loops for precise regulation of pressure, temperature, and process variables. Ensures stable and efficient operation in demanding marine and industrial environments.
  • Multi-Protocol Communication Support: Equipped with Modbus RTU, Modbus TCP/IP, EtherNet/IP, and CAN (J1939) communication capabilities, allowing seamless integration with PLCs, SCADA systems, HMIs, and engine ECUs.
  • Real-Time Monitoring and Shutdown Protection: Continuously monitors system inputs and triggers alarms or controlled shutdowns when operating limits are exceeded, enhancing equipment safety and reliability.
  • Event and Alarm History Logging: Stores shutdown events, alarm history, and operational data for improved diagnostics, troubleshooting, and preventive maintenance planning.
  • Non-Volatile Memory Storage: Configuration settings and set points are stored in non-volatile memory, ensuring data retention even during power interruptions.
  • Designed for Harsh and Hazardous Environments: Built to operate in extreme temperature conditions and suitable for installations requiring industrial-grade certifications.
  • Reciprocating and Screw Compressors: Provides automated start/stop control, pressure regulation, and shutdown protection for single or multi-stage compressor systems.
  • Marine Engine Control Systems: Enables real-time monitoring, alarm management, and protection for engine-driven systems onboard vessels and offshore equipment.
  • Oil & Gas Installations: Suitable for hazardous area environments requiring reliable industrial control and communication integration.
  • Pump Control and Monitoring: Supports configurable inputs and outputs for automated pump operation and performance tracking.
  • Industrial Engine-Driven Equipment: Ideal for generators, auxiliary systems, and heavy-duty machinery requiring advanced monitoring and control functionality.
  • Remote Monitoring Integration: Compatible with SCADA and supervisory systems, enabling remote diagnostics and performance tracking.

Advanced control, monitoring, and diagnostics platform engineered for compressors, pumps, and industrial automation systems.

Category Details
System Overview Fully configurable control and monitoring system for compressors and pump applications
Configurability Windows-based software with point-and-click setup (no programming required)
Control Capability Supports up to eight control loops (ISA PID / Linear)
Data & Diagnostics Active alarms, shutdown history (20 events), event history (32 events)
Maintenance Features 10 configurable maintenance timers, run hourmeter
Protection Features Short cycle protection, starts/hour control, compressor rod load calculation
Memory Non-volatile flash (configurations) & EEPROM (set points)
Mounting DIN rail mountable
Compatibility Backward compatible, upgradeable to M-View® displays
C5 Module – Operating Temp -40°C to +85°C
Power Input 10–30 VDC (30 W max)
Analog Inputs 12 channels (0–24 mA / 0–5 VDC, 15-bit)
Digital Inputs 32 inputs (NO/NC, intrinsically safe, fault detection)
Temperature Inputs J/K thermocouples, 3-wire 100Ω RTD with fault detection
Outputs 10 digital (relay + FET), 4 analog (4–20 mA)
Communication RS232, RS485, Ethernet, CAN, USB, optional WiFi
Protocols Modbus RTU, Modbus TCP/IP, EtherNet/IP, CAN (J1939)
MX4-R2 Module Thermocouple & RTD expansion with magnetic pickup input
MX5-R2 Module Expanded digital/analog I/O with FET outputs and signal inputs
M-View® MV-5-C 320×240 LCD, keypad interface, Modbus RTU communication
M-View® MV-7T / MV-12T Touchscreen displays, Ethernet, Modbus, EtherNet/IP support
TC / TCM Displays Up to 1280×800 resolution, 4GB memory, multi-protocol support
Certifications Class I Div 2, ATEX Zone 2, IECEx, UL, CE, RoHS compliant
Installation Requirement Designed for use within weatherproof enclosures

How the How the Centurion™ C5 Series Controller Works

The Centurion™ C5 Series Configurable Controller continuously monitors field inputs such as pressure, temperature, speed, and digital status signals from connected equipment. These inputs are compared against configured set points within the controller.

When process variables approach predefined limits, the system automatically adjusts outputs using configurable PID or linear control logic. This ensures stable compressor, pump, or engine operation while maintaining efficiency and safety.

If an out-of-limit condition occurs, the controller can trigger alarms, initiate controlled shutdown sequences, or communicate fault information to supervisory systems through Modbus, Ethernet, or CAN protocols. This integrated monitoring and control approach improves reliability and reduces downtime in marine, oil & gas, and industrial environments.

Technical FAQ

Common Questions Answered

Can't find your answer? Contact our engineers →

It is used for monitoring and controlling compressors, pump systems, and engine-driven industrial equipment. The controller provides real-time data, alarm management, and automated shutdown protection.

Yes, the Centurion C5 Series supports Modbus RTU and Modbus TCP/IP, allowing integration with PLCs, SCADA systems, and HMIs.

Yes, optional expansion modules are available to increase analog, digital, and temperature input capacity for complex industrial applications.

The system is designed for industrial environments and supports installations requiring certified control equipment for demanding operating conditions.

Yes, it stores alarm history, shutdown events, and operational logs to support diagnostics and preventive maintenance.

Free Technical Consultation

Get Your Datasheet
+ Quote in 24 Hours

Our engineers will recommend the right display for your specific application, send you the full technical datasheet, and provide a competitive quote.

  • Response guaranteed within 24 hours
  • Full technical datasheet included
  • Protocol compatibility guidance
  • OEM & bulk pricing available

Quick Quote Request

No spam ever · Response within 24 hours

Our Product Partners
Enovation Controls FW Murphy Production Controls Austart Air Starters MCS Mobile Control Systems AXI International Pacbrake Engine Exhaust Senquip Telemetry Enovation Controls FW Murphy Production Controls Austart Air Starters MCS Mobile Control Systems AXI International Pacbrake Engine Exhaust Senquip Telemetry