The Centurion C5 MX Series I/O Modules — comprising the MX4-R2 and MX5-R2 — are plug-in expansion modules designed to extend the signal capacity of the Centurion C5 configurable controller. The MX4-R2 adds thermocouple and RTD temperature monitoring capability for multi-point temperature measurement, while the MX5-R2 expands analog and digital I/O for broader process monitoring and control. Both modules are software-configured, require no hardware jumpers, and are certified for Class 1 Division 2 and ATEX/IECEx Zone 2 hazardous environments — making them the go-to solution for reciprocating and screw compressors, pump packages, and complex multi-stage industrial applications where the base C5 module I/O count needs to be increased.
The Centurion C5 MX Series expansion I/O modules are engineered to grow with the demands of your control application. When a gas compressor, pump system, or industrial process requires more thermocouple inputs, additional analog measurement channels, or extra digital switching capacity than the C5 main module provides on its own, the MX4-R2 and MX5-R2 slot directly into the system without special cables or complex wiring changes. Configured entirely through the Windows-based Centurion Configuration Software — with no jumper settings required — these modules bring certified hazardous area I/O expansion to three-to-four-stage compressor packages, engine-driven pump systems, and multi-loop process control panels. With an operating range of -40°C to +85°C, 10–30 VDC power supply compatibility, and internationally recognized ATEX and IECEx Zone 2 approvals, the MX Series modules deliver proven reliability in even the most challenging field environments.
Specifications are listed below for the Centurion C5 Main I/O Module, MX4-R2 Expansion I/O Module, and MX5-R2 Expansion I/O Module for engineering reference and procurement purposes.
| Parameter | C5 Main I/O Module | MX4-R2 Expansion | MX5-R2 Expansion |
|---|---|---|---|
| Operating Temperature | -40° to +185°F (-40° to +85°C) | -40° to +185°F (-40° to +85°C) | -40° to +185°F (-40° to +85°C) |
| Power Input | 30 W max, 10–30 VDC | 14.1 W max, 10–30 VDC | 16.5 W max, 10–30 VDC |
| Configuration Method | PC-based Centurion Configuration Software | PC-based Centurion Configuration Software | PC-based Centurion Configuration Software |
| Analog Inputs | 12 × (0–24 mA or 0–5 VDC, 15-bit); 4 configurable for potentiometer | — | 10 × (0–24 mA or 0–5 VDC, 15-bit hardware) |
| Digital Inputs | 32 × NO or NC, optically isolated with LED indicators; intrinsically safe; wire fault detection | — | — |
| Temperature Inputs | 8 × J/K thermocouple or 3-wire 100Ω Pt RTD; cold junction compensation; wire fault detection | 18 × J/K thermocouple (up to 9 convertible to 3-wire 100Ω Pt RTD); cold junction compensation; wire fault detection | — |
| Digital Outputs | 10 total: 4 relay (Form C, dry contacts), 4 FET (source), 2 FET (sink); LED indicators | — | 6 × FET (sink) |
| Analog Outputs | 4 × 4–20 mA, 16-bit hardware | — | 4 × 4–20 mA, 16-bit hardware |
| Magnetic Pickup / AC Run Signal | 1 × 30 Hz–10 kHz, 4.5 VAC rms min, 120 VAC rms max | 1 × 4.5 VAC–120 VAC, 30 Hz–10 kHz | 1 × 4.5 VAC–120 VAC, 30 Hz–10 kHz |
| Communication Ports | 2 × RS232 Modbus RTU; 2 × RS485 Modbus RTU; 1 × USB Host Type A; 1 × USB Server Type B; 2 × CAN (proprietary + J1939); 2 × Ethernet 10/100 DLR (Modbus TCP/IP, EtherNet/IP CIP); 1 × Wi-Fi (C5-1 only) | Via C5 main module | Via C5 main module |
| Real-Time Clock | Battery backed; ~10 years unpowered service life | — | — |
| I/O Selection | All I/O software selectable; no jumpers required | All I/O software selectable; no jumpers required | All I/O software selectable; no jumpers required |
| Hazardous Area Rating (North America) | Class 1, Div 2, Groups A, B, C, D; Class I Zone 2 | Class 1, Div 2, Groups A, B, C, D; Class I Zone 2 | Class 1, Div 2, Groups A, B, C, D; Class I Zone 2 |
| ATEX Certification | Zone 2, II 3G Ex ec [ic] nC IIC T4 Gc; DEMKO 18 ATEX 1926X | Zone 2, II 3G Ex ec [ic] IIC T4 Gc; DEMKO 18 ATEX 1926X | Zone 2, II 3G Ex ec [ic] IIC T4 Gc; DEMKO 18 ATEX 1926X |
| IECEx Certification | Zone 2, Ex ec [ic] nC IIC T4 Gc X; IECEx UL 18.0072X | Zone 2, Ex ec [ic] IIC T4 Gc X; IECEx UL 18.0072X | Zone 2, Ex ec [ic] IIC T4 Gc X; IECEx UL 18.0072X |
| Input Safety Classification | All digital/analog inputs intrinsically safe and non-incendive | All temperature inputs intrinsically safe and non-incendive | All analog inputs intrinsically safe and non-incendive |
The MX4-R2 and MX5-R2 expansion modules operate as integral extensions of the Centurion C5 control system. Once connected to the C5 main I/O module, the expansion modules are automatically recognized and their I/O points become available within the Centurion Configuration Software environment. Configuration is handled entirely in software — the operator selects channel types, input ranges, engineering unit scaling, alarm setpoints, and output behaviors through the point-and-click Windows interface without setting any physical jumpers or modifying wiring.
In normal operation, the C5 main module continuously scans all connected I/O — including the additional channels provided by the MX expansion modules — and compares live signal values against configured setpoints. When the MX4-R2 detects a thermocouple or RTD reading that crosses an alarm or shutdown threshold, or when the MX5-R2 receives an analog signal from a pressure or flow transmitter that falls outside defined limits, the C5 controller executes the configured response: activating an alarm output, commanding a shutdown sequence, or adjusting an analog control output to bring the process back within safe parameters. Wire fault detection on temperature inputs immediately alerts the controller to open-circuit or short-circuit conditions, preventing false readings from triggering spurious actions or masking genuine process faults.
All process data gathered by the expansion modules is accessible via the C5 communications ports — Modbus RTU, Modbus TCP/IP, or EtherNet/IP — allowing SCADA systems, HMIs, and PLCs to retrieve readings from every expansion module channel alongside the main C5 I/O on a single unified data connection. This consolidated architecture simplifies integration and reduces the communication infrastructure required at both local panel and remote monitoring levels.
The MX4-R2 and MX5-R2 are expansion I/O modules that plug into the Centurion C5 configurable controller to increase its signal handling capacity. The MX4-R2 adds thermocouple and RTD temperature inputs for multi-point temperature monitoring on compressors, engines, and pump systems. The MX5-R2 adds analog inputs, analog outputs, digital outputs, and a magnetic pickup input for applications requiring additional analog and digital I/O beyond the C5 main module's built-in capacity. Both modules are widely used on three-to-four-stage compressor packages and complex pump systems where the base C5 module channel count is insufficient for all required measurement and control points.
The MX4-R2 is a temperature-focused expansion module, adding up to 18 J/K-type thermocouple inputs and up to 9 three-wire 100Ω Pt RTD inputs, along with one magnetic pickup input. It is the right choice for applications requiring extensive temperature monitoring such as multi-stage gas compressors with numerous cylinder and cooler temperature points. The MX5-R2 is an analog and digital I/O expansion module, adding 10 analog inputs (0–24 mA or 0–5 VDC), 6 FET digital outputs, 4 analog outputs (4–20 mA), and one magnetic pickup input — suited to applications needing extra pressure transmitter inputs, flow signals, or additional proportional control outputs.
Yes. Both the MX4-R2 and MX5-R2 carry third-party hazardous area certifications covering Class 1, Division 2, Groups A, B, C, D for North America; Class I Zone 2; ATEX Zone 2 for Europe and international projects; and IECEx Zone 2 for global installations. All digital inputs, analog inputs, and temperature inputs are classified as intrinsically safe and non-incendive, making the modules suitable for installation in control panels serving natural gas compressor stations, offshore production platforms, refineries, and similar classified locations.
Configuration is carried out through the PC-based Centurion Configuration Software, which connects to the C5 system via USB or a serial port. All I/O channels on both MX modules are software-selectable — no physical jumpers are needed to define input types, signal ranges, or output modes. The software provides a graphical point-and-click interface for setting alarm thresholds, shutdown setpoints, control loop parameters, and display options. Configuration templates for common applications are included, and no programming experience is required to commission the system.
All communications are handled through the C5 main I/O module, which the MX expansion modules integrate with directly. The C5 supports Modbus RTU via two RS232 ports and two RS485 ports, Modbus TCP/IP and EtherNet/IP (CIP) via two 10/100 Ethernet ports with Device Level Ring (DLR) support, J1939 via a dedicated CAN port for electronic engine ECU communication, and optional Wi-Fi on the C5-1 variant. All expansion module I/O points are accessible on this unified communication interface, simplifying SCADA and HMI integration for the complete system.
Both the MX4-R2 and MX5-R2 are rated for continuous operation across -40°F to +185°F (-40°C to +85°C). This wide operating range supports installation in outdoor industrial enclosures across arctic, temperate, and high-ambient-temperature environments without requiring supplemental heating or cooling in most standard applications. Both modules accept 10–30 VDC power input, consistent with the C5 main module and most industrial DC power supply standards.
Our engineers will confirm the correct Centurion C5 main module and MX Series expansion module configuration for your application, advise on I/O channel requirements and hazardous area certification suitability, provide the full technical datasheet and wiring guidance, and deliver a competitive quote tailored to your project specifications.