The PowerHalt PH2 is an emergency air intake shut-off valve that provides a reliable and safe method of stopping a diesel engine during a runaway event. Designed for extreme environments, this valve is the positive air shut-off solution of choice for the heavy-duty diesel industry.
The Pacbrake PowerHalt PH2 is a positive air shut-off valve engineered to prevent catastrophic damage from diesel engine runaway by instantly cutting off the engine's air supply. Utilizing a robust butterfly valve design with a spring-loaded valve plate, the PH2 installs directly into the engine's intake hose and remains in a normally open (engine run) position until activated. This emergency shut-off valve is available with manual, electric (12/24 VDC), or pneumatic activation, and in sizes ranging from 2.8 to 5.5 inches. The PowerHalt PH2 is the ideal safety solution for Class 3-5 pickup trucks, Class 6-8 commercial vehicles, and stationary diesel equipment.
The PowerHalt PH2 combines robust engineering with multiple activation options to deliver reliable emergency engine shutdown. Its durable construction and smart design ensure protection in the harshest operating conditions.
Detailed specifications for the PowerHalt PH2 emergency air intake shut-off valve. All models are 12 VDC unless otherwise stated. Electric actuators feature a 10-second on / 90-second off duty cycle.
| Parameter | Specification |
|---|---|
| Valve Type | Positive Air Shut-Off Butterfly Valve |
| Nominal Valve Sizes (OD) | 2.8″, 3.0″, 3.5″, 4.0″, 5.0″, 5.5″ |
| Activation Methods | Manual (Pull Cable), Electric (12/24 VDC Solenoid), Pneumatic |
| Control / Reset | Manual / Manual (Standard); Auto / Manual (Optional with PowerGuard) |
| Electric Motor Resistance (12 VDC) | 1.7 Ω +/- 10% |
| Electric Motor Resistance (24 VDC) | 3.9 Ω +/- 10% |
| Duty Cycle | 10 sec ON / 90 sec OFF |
| Electrical Connector | Metri-Pack 280 Series, Female, 2-Pin (Delphi #15300027) |
| Actuator Weight | 0.84 kg (1.9 lb) |
| Pull Cable Activation Force | 90 N (20.2 lbf) |
| Minimum Pull Cable Stroke | 12 mm (0.47 in) |
| Default Position | Normally Open (Engine Run) |
| Power Supply | 12 VDC or 24 VDC |
| Operating Temperature (Solenoid) | -40°C to +70°C (-40°F to +158°F) |
| Pneumatic Activation Supply Pressure | 4.1 bar(g) [60 psig] min, 10 bar(g) [145 psig] max |
The Pacbrake PowerHalt PH2 is an emergency air intake shut-off valve that stops a diesel engine by blocking its air supply. In a normally open position, the butterfly valve allows air to flow freely to the engine. During a diesel runaway event—where the engine begins to run uncontrollably on its own oil or flammable vapors—the operator activates the PH2 by pulling a cable, pressing a button, or toggling a switch. For automatic models, the PowerGuard controller continuously monitors engine RPM and triggers the valve when an overspeed condition is detected. Upon activation, the spring-loaded valve plate snaps shut, instantly cutting off the air supply and forcing the engine to stop. The PH2 uses a manual latching system, meaning the valve remains closed until it is manually reset, ensuring the engine cannot be restarted until the operator has physically returned the valve to its open position.
Diesel engine runaway is an uncontrolled acceleration of the engine caused by an external fuel source, such as engine oil from a blown turbo seal or flammable vapors. The engine continues to run even when the key is turned off, leading to catastrophic mechanical failure, fire, or explosion.
The PowerHalt PH2 is a positive air shut-off valve. When activated, it instantly blocks the engine's air intake, cutting off the oxygen supply required for combustion. This action forces the engine to stop quickly and safely, preventing damage.
Manual activation requires an operator to trigger the valve (pull cable or press a button). Automatic activation uses the PowerGuard controller, which monitors engine RPM and automatically shuts down the engine if it exceeds a user‑set trip speed.
The PH2 is designed for minimal maintenance. Regular visual inspections of the valve, intake hoses, and clamps are recommended. The valve can be tested by activating it at low idle to ensure proper operation and then manually resetting it.
The PowerHalt PH2 is available in nominal sizes from 2.8″ to 5.5″. You should select the size that matches the inner diameter of your engine's intake hose. If you are unsure, our team can help you identify the correct size based on your engine make and model.
Our engineers will confirm the correct PowerHalt PH2 configuration, activation type, valve size, and installation requirements — and provide full technical documentation and a competitive quote matched to your engine type and operating environment.